How to Fix Xhorse Dolphin XP005/XP005L Error Code 80: Device Initialize Error?

Issue:

Use Xhorse Dolphin XP005L alone or use Dolphin XP005 with Key Tool Max Pro/smartphone to cut keys, appears “error code 80, device initialize error” as shown in the figures below.

Xhorsetool.com engineers suggestion:

1.Update firmware, calibrate machine, and try again

2.If not solve, go to perform Electrical Conductivity Measurement

Device information>> Electrical conductivity measurement>> follow the on-screen instruction below to test

Use a blank key or any other conductor to connect the probe and clamp/cutter and clamp in sequence to measure

3.If it shows “error 80, device calibration error can’t do universal key duplication”, maybe the dolphin key cutting machine is short-circuited, check if wires are broken or loose.

4.If all methods above still cannot fix the error, it needs to replace the main PCB.

Provide your device SN to your dealer, if it’s under the warranty, and you can apply a new PCB free.

 